CONTEC ICU Vital Sign Patient Monitor, NIBP+SPO2+PR with Software PM50 Portable

CONTEC ICU Vital Sign Patient Monitor, NIBP+SPO2+PR with Software PM50 Portable
  • Продавецflimmer.com
  • Список ценUS $199.91piece
  • Продажная ценаUS $199.91piece
  • ДоставкаБесплатная доставка
  • Рейтинги3,1 (236)

Oписание продукта

We are manufacturer: Contec Medical Systems
CMS6000C ICU Patient Monitor ECG/EKG/NIBP,SPO2,PR,RESP,TEMP, 3-Parameters,CONTECModel:CMS6000C 
The monitor is registered on the Australian
 Register of Therapeutic Goods(ARTG) with the code 197923

4

 

 

 

 

 

 

 

 

 

Features:

8.4” color TFT display

Unique digital SPO technology with excellent measurement and interference-free

Audible and visual alarms with adjustable alarm range

Anti electrosurgical interference and defibrillation

Can be connected with LAN to work with central monitoring system

Powerful data management and storage capacity

Suitable for adult, pediatric and neonatal patient

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection: I, II, III, avR, avL, avF, V

Waveform: 2 ch

Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV

HR and Alarm Range:

Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy: ±1% or ±1bpm, which great

Resolution: 1 bpm

Sensitivity: >200uV P-P

Differential Input Impedance: >5MΩ

CMRR:

Monitor: >105dB

Operation: >105dB

Diagnosis: >85dB

Electrode offset potential: 300mV

Leakage Current: <10uA

Baseline Recovery: <3s after Defi.

ECG Signal Range: 8mV(Vp-p)

Calibration Signal: 1mV (Vp-p), 5% Accuracy

ST Segment measure and alarm: -2.0 ~ +2.0 mV

NIBP

Method: Oscillometry

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90Min

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm Range

Adult Mode:

SYS: 40 ~ 270 mmHg

DIA: 10 ~ 215 mmHg

MEAN: 20 ~ 235 mmHg

Pediatric Mode

SYS: 40 ~ 200 mmHg

DIA: 10 ~ 150 mmHg

MEAN: 20 ~ 165 mmHg

Neonatal Mode

SYS: 40 ~ 135 mmHg

DIA: 10 ~ 100 mmHg

MEAN: 20 ~ 110 mmHg

Resolution: 1mmHg

Over-pressure protection: YES

SpO2

- Measuring Range: 0 ~ 100%

- Alarm Range: 0 ~ 100%

- Resolution: 1%

- Accuracy:

70% ~ 100%: 2 %

0% ~ 69%: unspecified

- Actualization interval: About 1Sec.

- Alarm Delay: 10 Sec.

- Pulse Rate

Measuring and Alarm Range: 0~254bpm

- Resolution: 1bpm

- Accuracy: 2bpm

- Alarm Delay: 10 Sec.

 

Standard Configuration:

ECG, NIBP, SpO2,PR, Built-in Rechargeable Battery,ETCO2

Optional:

RESP,2-TEMP,2-IBP,Thermal Recorder

 

s-l1600 (9).jpgs-l1600 (1).jpgs-l1600 (3).jpgs-l1600 (2).jpgs-l1600 (4).jpgs-l1600 (5).jpgs-l1600 (7).jpgs-l1600 (8).jpg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cuff

adult probe

 

NIBP

POWER  CABLE

ELECtrodes

ECG  ceble

temp  probe